Changing Member Disks in an SSA RAID Array
This option allows you to remove a disk drive from an array and install a replacement
disk drive. All the data that is on the original disk drive is automatically written to the
replacement disk drive.
1. For fast path, type smitty swpssaraid and press Enter.
Otherwise, select Change Member Disks in an SSA RAID Array from the SSA
RAID Arrays menu.
2. The following menu is displayed:
Change Member Disks in an SSA RAID Array
Move cursor to desired item and press Enter.
Remove a Disk From an SSA RAID Array
Add a Disk to an SSA RAID Array
Swap Members of an SSA RAID Array
F1=Help F2=Refresh F3=Cancel F8=Image
F9=Shell F10=Exit Enter=Do
If you have an available disk drive, select Swap Members of an SSA RAID Array,
and go to step 2 on page 142 of Swapping Members of an SSA RAID Array.
If you do not have an available disk drive, select Remove a Disk from an SSA
RAID Array, and go to step 2 on page 138 of Removing a Disk Drive from an SSA
RAID Array.
Chapter 6. Using the RAID Array Configurator 137