Output
The ssa_speed command sends all error messages to stderr, and output to stdout.
Link speeds can be:
v 20 (20 MB)
v 40 (40 MB)
v 00 (not operational)
v ?? (not determined)
Examples
v To display the link speed of pdisk0, give the command:
ssa_speed -l pdisk0
v To display the adapter link speeds of ports A1 and A2 on ssa0, give the command:
ssa_speed -a ssa0 -p A
v To display the adapter link speeds of all the devices in network B on ssa0, give the
command:
ssa_speed -a ssa0 -n B
v To find link speed exception conditions, give the command:
ssa_speed -x