Compex-systems Advanced SerialRAID Adapters SA33-3285-02 Manuel d'utilisateur Page 222

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 531
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 221
RAID-1 Failure of a Host System and a Primary Disk Drive: Figure 35 shows
system 2 disconnected from system 1. The array is in the Offline state. If you set Split
Array Resolution to Secondary, the array goes into the Good state.
RAID-10 Failure of a Host System and a Primary Disk Drive: Figure 36 shows
system 2 disconnected from system 1. The array is in the Offline state. If you set Split
Array Resolution to Secondary, the array goes into the Good state.
Secondary 1
Split Array Resolution
= Primary
System 2
SSA Adapter
Figure 35. RAID-1 Failure of a Host System and a Primary Disk Drive
Split Array Resolution
= Primary
System 2
SSA Adapter
Secondary 1
Secondary 2
Figure 36. RAID-10 Failure of a Host System and a Primary Disk Drive
202 Users Guide and Maintenance Information